{"product_id":"breaker-2p-63a-schneider-domae","title":"Breaker 2P 63A Schneider (Acti9 iC60N 2P 63A C Miniature Circuit breaker)","description":"\u003cp data-path-to-node=\"0\"\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"0\"\u003eProduct Overview\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"0\"\u003eEnsure premium commercial and industrial-grade electrical safety with the \u003cb data-path-to-node=\"0\" data-index-in-node=\"91\"\u003eSchneider Acti9 iC60N 2-Pole 63A Miniature Circuit Breaker (MCB)\u003c\/b\u003e. Part of Schneider’s high-performance \u003cb data-path-to-node=\"0\" data-index-in-node=\"194\"\u003eActi9 range\u003c\/b\u003e, this advanced multi-standard circuit breaker provides top-tier protection against \u003cb data-path-to-node=\"0\" data-index-in-node=\"289\"\u003eoverloads and short-circuits\u003c\/b\u003e. Designed for seamless integration into low-voltage distribution systems, it features an enhanced breaking capacity, clear fault indication, and \u003cb data-path-to-node=\"0\" data-index-in-node=\"463\"\u003eautomatically disconnects the circuit\u003c\/b\u003e instantly during hazardous electrical faults to prevent equipment damage.\u003c\/p\u003e\n\u003cp data-path-to-node=\"1\"\u003ePerfectly calibrated for high-demand electrical networks, the \u003cb data-path-to-node=\"1\" data-index-in-node=\"62\"\u003eSchneider Acti9 iC60N 63A MCB\u003c\/b\u003e delivers effortless installation, multi-standard compliance, and robust long-term operational safety for your \u003cb data-path-to-node=\"1\" data-index-in-node=\"202\"\u003epower distribution paths, motors, and industrial appliances\u003c\/b\u003e.\u003c\/p\u003e\n\u003cdiv class=\"attachment-container search-images\"\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003cp data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eKey Features \u0026amp; Benefits\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"24\"\u003eDual Protection \u0026amp; High Breaking Capacity:\u003c\/b\u003e Offers superior, industrial-grade protection against electrical overloads and short-circuits.\u003c\/p\u003e\n\u003cp data-path-to-node=\"6\"\u003e\u003cb data-path-to-node=\"6\" data-index-in-node=\"0\"\u003eC-Curve Tripping Characteristic:\u003c\/b\u003e Optimized for handling inductive loads with moderate inrush currents, making it ideal for commercial lighting networks, small motors, and general power distribution.\u003c\/p\u003e\n\u003cp data-path-to-node=\"7\"\u003e\u003cb data-path-to-node=\"7\" data-index-in-node=\"0\"\u003eVisiSafe \u0026amp; VisiTrip Indicators:\u003c\/b\u003e Features visible green strips for safe downstream maintenance isolation and a dedicated red indicator to identify faulty tripped circuits at a glance.\u003c\/p\u003e\n\u003cp data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003ePremium Fire-Resistant Build:\u003c\/b\u003e Constructed using high-grade, fire-resistant materials that endure extreme thermal stress, abnormal heating, and heavy physical impacts.\u003c\/p\u003e\n\u003cp data-path-to-node=\"9\"\u003e\u003cb data-path-to-node=\"9\" data-index-in-node=\"0\"\u003eVersatile Din-Rail Mounting:\u003c\/b\u003e Provides highly secure, tool-free installation onto standard DIN rails with reinforced terminal connections for maximum operational stability.\u003c\/p\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable data-path-to-node=\"12\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,1,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,1,1,0\"\u003eSchneider Electric (Acti9 Range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,2,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,2,1,0\"\u003eiC60N (A9F44263)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,3,0,0\"\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,3,1,0\"\u003eMiniature Circuit Breaker (MCB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,4,0,0\"\u003eNumber of Poles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,4,1,0\"\u003e2-Pole (2P)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,5,0,0\"\u003eRated Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,5,1,0\"\u003e63A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,6,0,0\"\u003eTripping Curve\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,6,1,0\"\u003eC Curve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,7,0,0\"\u003eRated Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,7,1,0\"\u003e220V - 415V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,8,0,0\"\u003eApplication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,8,1,0\"\u003eOverload \u0026amp; Short-Circuit Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-path-to-node=\"0\"\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":48117331755229,"sku":null,"price":7000.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/3692\/2333\/files\/2P_Schneider_63A_front_View_97ec7edf-72d4-4158-b791-cb301d84f85c.png?v=1783063702","url":"https:\/\/www.hijazi.pk\/products\/breaker-2p-63a-schneider-domae","provider":"Hijazi Electric and Sanitary","version":"1.0","type":"link"}